Log in
Billing
Invoices
All unpaid invoices
Invoices needing signatures
Invoices out for signatures
Invoices needing to be submitted
Invoices waiting on payment
Edit status
Delivery Tickets
All open delivery tickets
Midland open tickets
Corpus open tickets
Pennsylvania open tickets
Repairs
All Repairs
All open Repairs
Odessa open Repairs
Corpus open Repairs
Pennsylvania open Repairs
Unpaid Repairs
Non Compliance
NCR List
Wiki
Drilling Rigs
US Rigs
Permian Basin
Gulf Coast
ArkLaTex
Louisiana
Mid-Con
Oklahoma
North Dakota
North East
Pennsylvania
Ohio
Rockies
North Dakota
Colorado
Gulf of Mexico
Permits
US Permits
Permian Basin
Gulf Coast
ArkLaTex
Louisiana
Mid-Con
Oklahoma
North Dakota
North East
Pennsylvania
Ohio
Rockies
North Dakota
Colorado
Gulf of Mexico
Customers
MSA list
Directions
Cheapeake
EOG Resources
Compiled
Non Conformance Report
Delivery Ticket: 22227
Office: ODE
Customer: XTO ENERGY INC.
Well Name: BRADFORD TRUST 1218AH
Contractor: None
Ordered by: None
Job Type: FRAC STACK
Datetime reported:
Downtime start:
Downtime stop:
Email:
dmckim@exactvalvesolutions.com
Send email:
Unknown
Yes
No
Evs number:
Equipment description:
Priority:
Low
Medium
High
Status:
Open
Closed
Problem:
March 13th 11:30pm 1217ah Stream of water pouring out through the weephole. They did a stage while waiting on the plugs. March 14th 7:20 am going to set a retrievable. Had to wait on plugs March 14th one of the new valves was leaking. Swap it out 4:30am the valves tested good This is the 1217, not the 1218
Problem type:
---------
Bonnet Leak
Packing Leak
Ring Groove leak
Internal leak
Hydraulic leak
Non functioning
Other
Troubleshooting:
Broke down all the valves at the shop. All 4 had very little grease in the bodies but had a lot of sand. 3 of the 4 valve bodies were washed out and will need machine work.
Reason:
We are not getting enough grease in the valve bodies. We need to see what the reason is for that.
Solution:
Gene went to location and talked to the supervisors about greasing the valves. He also made sure they were following our greasing procedures and that we are greasing often enough.
Submit